Common Applications

Dimensions - Available in 1/2" 2'x4', 4'x4', 4'x8' and 1" 2'x4', 4'x4', 4'x8'
Application
RoofRite roof insulation may be used under fully adhered, looselaid, ballasted or mechanically fastened single-ply roofing systems. RoofRite and Roof Board may be used as a general purpose insulation recovery board separating new from existing reroofing construction and under conventional built-up and modified bitumen roofing systems.

When used in a reroofing application, remove all loose and protruding gravel and other debris from the existing roof. Deck must be dry and any wet areas in the old roof must be removed and replaced before new application.

Apply only as much insulation as can be covered by the roof membrane in the same day. Panels must always be stored and applied dry.

Notes:


1. Use only High Density Grade 2 woodfiber roofboard (as referenced in ASTM C208-95) under fully adhered single ply systems.

2. Do not apply flame directly to roof insulation when installing a modified bitumen system.

Warning: Woodfiber may smolder or ignite if exposed to open flame.

Recommended Fastening Pattern
If used in a specific system, always follow the system's specified fastening recommendation.

When using RoofRite High Density roof insulation, only Factory Mutual approved fasteners should be used on fully adhered or mechanically attached membrane systems.
Fully Adhered
Mechanically Fastened